fbpx
Contact Us Today
Toll-FREE

Refurbished OEC 6800 C-arm

Refurbishing Process:
All OEC-6800’s go through a multi-step refurbishing process. Each unit is restored to a like-new status. Hand Surgeons, Podiatrists, Orthopedics, Rehabilitation Services are just a few of the applications utilizing the refurbished OEC-6800 C-arm. The Advanced Technology 1Kx1K CCD Camera Technology used in the OEC-6800 image system allows for crisp clear imaging. Whatever the purpose, a refurbished OEC-6800 will deliver the results you can depend on.

Mechanical repairs/cosmetic
maintenance

  • All defective parts and covers are repaired or replaced
  • C-arm is completely disassembled and repainted
  • “C” is removed from main frame assembly
  • Image intensifier removed and inspected for any imperfections and grid integrity
  • Camera removed, cleaned and tested to OEM Specs
  • Wheels removed, cleaned and or replaced from main chassis
  • Chassis inspected for structural defects and repaired as necessary
  • All bearings are inspected, cleaned and re-lubricated, or replaced as needed
  • Control panel display is tested and replaced if necessary
  • All wheels are inspected and lubricated and/or replaced as needed, with new cable pushers installed
  • All locks and brake assemblies are inspected, cleaned, and repaired or replaced as needed
  • C-arm is completely disassembled and repainted
  • A complete set of operator and service manuals are provided

Re-assembly

  • All components sent to C-arm reassembly area for rebuilding
  • “C”, Image tube and camera, Vertical column, main control and power cable installed
  • New CRT monitors installed in monitor cart
  • Monitor cart rebuilt
  • When C-arm is completely rebuilt mechanically, system is sent for calibration and final testing

Testing/calibration

  • Image intensifier and X-ray tube are tested for stability and balance
  • Image intensifier is tested for resolution and gain to be within OEM specifications
  • X-ray tube radiation output is verified to be within OEM specifications
  • X-ray generator high voltage tested
  • Maximum dose rate is set in compliance with government regulations
  • CCD camera calibrated to OEM specifications
  • X-ray beam is aligned for each field size
  • C-arm is tested for current leakage requirements
  • All monitors are aligned, resized, centered and focused
  • All monitors are adjusted for brightness and linearity
  • Video system is optimized for gray scale and resolution
  • All power supplies are tested and calibrated or replaced as necessary

Specifications
C-Arm Specifications:

  • Free Space: 12”
  • Depth: 14.5”
  • SID: 14.9”
  • Orbit Rotation: 110 degrees
  • Rotation: +/- 200 degrees
  • Wig-Wag: 180 degrees
  • Vertical Travel: 24”
  • Extension: Up to 55”

Mechanical Specs:

  • Height: 64”
  • Width: 27”
  • Depth: 27”
  • Footprint: 5 sq. ft.

Power Requirements:

  • Input power: 60Hz
  • 100-120V 15A
  • 200-240V 8A

Refurbished OEC 6800