Refurbished OEC 9800 C-arm
Refurbishing Process:
All OEC-9800’s go through a multistep refurbishing process. Each unit is restored to a like-new status. Pain Management, Orthopedics and Rehabilitation Services are just a few of the applications utilizing the refurbished OEC-9800 c-arm. The rotating x-ray tube allows for greater penetration and resolution for the lumbar area when doing needle localizations or other work involving the thicker anatomical areas of patients. For barium swallows a VCR or Digital Video Recorder can be utilized for better record keeping and post study analysis. The 1K X 1K CCD Technology used in the OEC-9800 image system allows for crisp, clear imaging. Whatever the purpose, a refurbished OEC-9800 will deliver the results you can depend on.
Mechanical repairs/cosmetic maintenance
- All defective parts and covers are repaired or replaced
- C-arm is completely disassembled and repainted
- “C” is removed from main frame assembly
- Horizontal arm removed, inspected and repaired as necessary
- Vertical column removed and bearings removed inspected and replaced as required
- X-ray tube removed and inspected for artifacts and internal integrity
- Image intensifier removed and inspected for any imperfections and grid integrity
- Camera removed
- Wheels removed, cleaned and or replaced from main chassis
- Chassis inspected for structural defects and repaired as necessary
- Vertical lift assembly is tested for drift and adjusted/replaced if necessary
- All bearings are inspected, cleaned and re-lubricated, or replaced as needed
- Control panel display is tested and replaced if necessary
- All wheels are inspected and lubricated and/or replaced as needed, with new cable pushers installed
- All locks and brake assemblies are inspected, cleaned, and repaired or replaced as needed
- C-arm is completely disassembled and repainted
- Steering is tested and adjusted is required
- Foot switch and hand switch provided on each unit
- A complete set of operator and service manuals are provided
Re-assembly
- All components sent to C-arm reassembly area for rebuilding
- “C”, Image tube and camera, Vertical column, main control and power cable installed
- New batteries are installed
- New CRT monitors installed in monitor cart
- Monitor cart rebuilt
- When C-arm is completely rebuilt mechanically system is sent for calibration and final testing
Testing/calibration
- Image intensifier and X-ray tube are tested for stability and balance
- Image intensifier is tested for resolution and gain to be within OEM specifications
- X-ray tube bearings are tested for noise and coast time
- X-ray tube filaments and stator windings are tested
- X-ray tube radiation output is verified to be within OEM specifications
- X-ray generator high voltage tested
- Maximum dose rate is set in compliance with government regulations
- CCD camera calibrated to OEM specifications
- X-ray beam is aligned for each field size
- C-arm is tested for current leakage requirements
- All monitors are aligned, resized, centered and focused
- All monitors are adjusted for brightness and linearity
- Video system is optimized for gray scale and resolution
- All power supplies are tested and calibrated or replaced as necessary
Specifications:
Technical Specificaitons Generator
- High frequency generator 15kW full-wave
- Up to 120 KVP and 75MA for radiographic exposures
- Continuous fluro-mode up to 20 mA
- One shot frame integration (low, medium, high)
- Full power from standard 110V 15A Or 220V 8A outlet
- Patented energy buffer design X-Ray Tube
- Rotating anode X-ray tube
- Focal spots: 0.3 – 0.6 mm
- 300,000 HU Anode heat capapcity
Physical Specificaitons
- Free Space in Arc – 31”
- Depth of Arc: 26”
- Arc orbital movement: 115 Degrees
- Left/Right wig-wag scan:
+/- 20 degrees - Vertical Travel: 18” motorized
- Horizontal travel: 8”
- Lateral rotation: +/- 180 degrees
C-arm Dimensions
- Length: 75.9”
- Height 69.9”
- Width: 33”
Workstation Dimensions
- Width: 27”
- Height 64”
- Depth: 27”