CUATTRO Arcus – 40Kw Mobile DR Solution Portable X-Ray

DEMO UNIT

Arcus – 40Kw Mobile DR Solution

Interface:
The CloudDR touchscreen wireless aqcuisition tablet can be easily removed for study review and presentation. The mounting points can be customized for placement almost anywhere on the system. Utilize multiple mounting points to maximize flexibility and workflow preferences.

40Kw Generator:

  • Kvp Range in 1Kvp Range in 1 KVp steps: 40 to 125
  • Accuracy: +/- (4% + 1mA)
  • Exposure time range: 0.001 – 10 seg.
  • Accuracy: +/-(2% +0.1ms)
  • mAs range: 0.1 – 500mAs
  • Operation Independent from main supply: Standard
  • Collimator: Manual with electronic timer and meter
  • Anatomical programmer: 492 views
  • Line voltage range and phases: Single – Phase line automatic regulation from 100 – 240 Vac (+/-10%)
  • Motor Driven Unit: Standard
  • Weight: 541Kg

14×17″ Wireless Detector
Sensor:

  • Panel: Single substrate amorphous silicon active TFT/diode array
  • Scintillator: Direct deposition CsI:Tl
  • Pixel Matrix: 3556 × 4320
  • Pixel Pitch: 100 μm

Electronics:

  • Amplifiers: Low noise ASICs with user selectable gains
  • ADC: 16 bit
  • Image Transfer Time: Wired: 500 ms; Wireless: 3000 ms
  • On Board Memory: 1 GB DDR3, 4 GB SDHC card
    Mechanical:
  • Size: ISO 4090 for 35 cm × 43 cm (14” × 17”) cassette size
  • Active Area: True 355 mm × 432 mm
  • External Dimensions: 384 mm (w) × 460 mm (l) × 15 mm (h)
  • Weight: 3.8 kg (8.4 lbs)
  • Housing: Carbon-fiber front & back

Communications:

  • Status Display: OLED display with WiFi, battery, and sensor indicators
  • Wireless Data I/F: 802.11n WiFi standard
  • Wired Data I/F: GigE via optional power & communication tether
  • X-ray I/F: Integrated X-ray trigger control. Automatic Exposure Detection

Imaging Performance:Limiting Resolution: 5 cy/mm

  • Typical MTF: 70% (1 cy/mm), 40% (2 cy/mm), 15% (4 cy/mm) for RQA5
  • Typical DQE: 75% (0 cy/mm), 60% (1 cy/mm), 40% (3 cy/mm) for RQA5

Environmental:

  • Temperature: 10 – 35 °C operating
  • Humidity: 30 – 70 % RH operating (non-condensing)

Power:

  • Battery: Rechargeable battery, 53.3 Wh
  • Battery Charger: External two bay charger 100-240 V AC 50/60 Hz
    Interface & Power Unit: Optional XRpad IPU with external power supply – 100-240 V AC, GigE, and X-ray I/F